RPIC-2017 Ion chromatograph

The RPIC-2017 ion chromatograph is an intelligent ion chromatograph released by Qingdao Reepo Analytical Instrument Co., Ltd. It has a reasonable structure and orderly distribution. It is equipped with a number of core technologies, a dynamic range conductivity det ector as standard, and a half-year maintenance-free suppressor. , All-plastic PEEK pump, hot air circulation integral thermostat; optional valve switching application, optional eluent generator.

  • Application field: Third-party testing

The RPIC-2017 ion chromatograph is an intelligent ion chromatograph released by Qingdao Reepo Analytical Instrument Co., Ltd. It has a reasonable structure and orderly distribution. It is equipped with a number of core technologies, a dynamic range conductivity det

ector as standard, and a half-year maintenance-free suppressor. , All-plastic PEEK pump, hot air circulation integral thermostat; optional valve switching application, optional eluent generator.

 

Feature

 

Eluent generator: only adding water

 

Only add water when configuring the eluent to avoid corrosion of the pump head

 

The eluent generator relies on the current to adjust the eluent, which is more accurate and can achieve gradient leaching

 

High pressure PEEK pump

 

More acid and alkali resistance than stainless steel pumps.

 

Dynamic range conductivity detector

 

Dynamic range,No need to set the range in advance, the detection signal range is not limited by the range

 

wide-range, and the peak area ratio of adjacent peaks Is 10000:1

 

Ion exchange membrane isolation sealed suppressor that are Long-life and low-maintenance

 

Performance is at the international advanced level with small size

 

Electric six-way valve

 

Avoid poor precision caused by uneven operation

 

intelligent control

 

A key to start the instrument

 

User-defined time program, you dominate all

 

Eluent exhausted remind

 

Automatic switch

 

Automatically associate related parts when the pump starts and stops

 

Turn on the pump and increase the flow rate slowly to protect the chromatographic column

 

System pressure limit

 

Run log for easy query

 

Suppressor overpressure remind

 

Multi-step control of eluent generator

 

Visual switch and switching operation

 

One-click start

 

Pump, valve, suppressor, flow rate, eluent generator, eluent volume monitoring and other operations and settings can be completed with one button.

 

The sample analysis program is user-defined, time program control, and analysis is completed by one button.

 

To use the instrument the next day, add the eluent or pure water in advance, set it to turn on 1 hour before work, and the instrument is stable after work, so you can just inject the sample directly, which saves time.

 

After the last sample of the day is injected, you do not need to wait for it to end before leaving get off work. Set automatic shutdown, and it will automatically shut down after the sample is taken.

 

Eluent exhausted reminder

 

Lower than the alarm value, remind to add Eluent

 

Lower than the shutdown value, automatic shutdown to avoid taking time out

 

The start and stop of the pump are automatically related to the start and stop of the eluent generator, and the start and stop are synchronized.

 

The start and stop of the pump are automatically associated with the start and stop of the suppressor, and the start and stop are synchronized to avoid damage to the suppressor.